Some differences between open type chillers and water tank chillers

2018-10-18 09:59:36 CUMOND MACHINERY

The classification of chillers is generally complicated. Many people are unclear. It is a very painful thing for companies that want to buy chillers. It can be divided into air-cooled according to the cooling method. Type chiller, water-cooled chiller, oil-cooled chiller, oil-cooled chiller are generally used less, currently mainly used air-cooled chiller and water-cooled chiller, while air-cooled chiller is cooled The amount is relatively small, generally used in the low-power refrigeration range, and the water-cooled chiller is used in a wide range, and most enterprises choose this chiller.

The chiller is subdivided and can be divided into an open chiller and hermetic chiller from the appearance.From the compressor type,we can say screw chiller,scroll chiller and piston chiller.

Cumond Plastic Auxiliary Machine

Today. We would explain you what is the main difference between the open type chiller and the water tank chiller .

1. Noun definition : 

Open chiller and water tank chiller belong to the series of water-cooled chillers. The open chiller mainly consists of a compressor, an evaporator, a condenser, an electric control system, and a refrigeration accessory assembly. The water-cooled chiller consists of a compressor, an evaporator, a condenser, a water pump, a water tank, an electric control system, and a freezing accessory. Therefore, it can be seen that the difference between the two is that the water-cooled box chiller can have a built-in water pump and a water tank, and vice versa, an open chiller.

2.Installation configuration : 

Chiller is mainly to provide frozen water to the product or equipment to achieve the purpose of refrigeration. Both types of chillers need to be equipped with a cooling tower for heat dissipation. However, since the water-cooled box chiller has a water tank and a water pump built in, the user only needs to connect the chiller to the cooling tower and connect the tap water to the input. use. In addition to the cooling tower, the open chiller also needs to be added with a water pump and a double-layer stainless steel insulated water tank.

3. Advantage analysis : 

The water-cooled box chiller has built-in stainless steel water tank and pipeline water pump. The appearance is beautiful and the configuration is perfect. The main components are protected by the steel body shell, which can be placed in the production workshop, which is easy to install and easy to use/maintain. The open chiller does not have its own water tank and water pump. It can be connected to the water pump and water tank as needed. The advantage is that the volume of the water tank and the pump head are not limited, which can better meet the needs of different industrial equipment.

Through the above tips, you should have a better understanding of industrial refrigeration, if you have any questions, you may wish to contact our sales : +86-139-7498-0769 ( WhatsApp ) .